Products

THP-IP122-AC 1 in 1 out Current Input Signal Isolator

型号

TS-SV/A

输入通道数量

TS-SV/A

典型输入信号

典型输入信号

输出通道数量

输出通道数量

典型输出信号

典型输出信号

供电电源

供电电源

附加功能

附加功能

Product details Product parameter Overall dimension Wiring diagram

Product details

Product details

Product parameter

Product parameter

Input end

Input signal: 0-20mA

Distribution voltage: Open circuit voltage ≤25VDC Voltage at 20mA:>15V 

Distribution working current: <25mA 

Input impedance: ≤50Ω

Output end

Output signal: 0-20mA

Output load resistance :RL≤500Ω(output current signal); 

Basic parameter

Power supply : AC/DC 85-265V

Rated power: ≤2W (20mA output)

Basic accuracy : 0.1%F.S 

Temperature drift : 0.005%F.S/℃ (-20℃~+55℃)

Response time : 10mS(0-90%)(TYP)

Insulation strength :1500V AC/1min (Between input, output and power supply)

Insulation resistance : >100MΩ (Input, output, power supply)

Operating temperature range : -20~+55℃

Electromagnetic compatibility: According to GB/T18268.1(IEC61326-1)

Applicable field equipment: Two-wire and three-wire transmitters, voltage source, current source signals

Use environment

(1) There must be no electromagnetic induction in the surrounding environment such as strong vibration, impact, large currents and sparks. The air should not contain media that corrodes chromium, nickel, and silver coatings, and should not contain flammable and explosive substances; 

(2) Storage temperature: -40℃~+80℃;

(3) Relative humidity: 10%~90%RH;

Overall dimension

Overall dimension

6.jpg



Wiring diagram

Wiring diagram


Note:

1. When the thermocouple is input, the compensation wire should be directly connected to the input terminal, and the conductor of other materials should not be connected in the middle, otherwise the measurement error will be caused.

2, the bus power supply and RS485 output function is optional, if necessary, please specify and purchase the bus power supply module when ordering. The TS-TC5XX has no 485 output function.